MUD TESTING EQUIPMENT
For years, Inmotion Energy has
supplied precision instruments
and drilling tools for testing
drilling fluids, well cements, and
completion fluids.
From our Bangalore facility, we
provide customers across India
and the Middle East with quality
products and exceptional
service.
INDUSTRIES WE SERVE
— Onshore & offshore drilling contractors
— National & independent oil companies
— Mud engineering & testing laboratories
— Well completion & workover operations
WHY CHOOSE US
— Rigorous quality control on every unit
— Fast turnaround on spares &
replacements
— Field-tested designs, built for uptime
INMOTION ENERGY (OPC) PRIVATE LIMITED
- 186, 1st Main Road, Vijaya Bank Layout, Bilekahalli, Bangalore, Karnataka – 560076
- Phone: +91 96637 44619
- info@inmotionenergy.in
- imotion.in
PRODUCT SPECIFICATION — HTHP FILTER PRESS, 175 mL CELL
HTHP Filter Press (175 mL Cell)
175 mL HTHP filter press for field and laboratory mud and cement testing
FEATURES
✔Full HTHP Test Condition: 4.2 MPa (600 PSI) cell pressure against 0.7 MPa (100 PSI) back-pressure — a 3.5
MPa (500 PSI) differential at up to 232°C (450°F), the standard API RP 13B-1, Sec. 7.2 test condition.
✔Dual-Cell Compatibility: through-hole cup and double-screen cover let the same press test drilling fluids
and cement slurries.
✔Insulated Heating Jacket: high heat-transfer efficiency brings the cell to temperature quickly and holds it
there.
✔Back-Pressure Receiver: collects filtrate under regulated pressure so it doesn’t flash off at temperature.
Runs on AC220V 50Hz (standard) or AC120V 60Hz (USA), ±10%.
TECHNICAL SPECIFICATIONS
| Inmotion Model Number | IM-FP-HTHP175 |
| Configuration | 175 mL HTHP Cell, Heated & Pressurized |
| Sample Cup Options | Standard, and Through-Hole (cement) |
| Cell Pressure | 4.2 MPa (600 PSI) |
| Differential Test Pressure | 3.5 MPa (500 PSI) |
| Working Temperature | To 232°C (450°F) max — 150°C (300°F) typical test |
| Test Duration | 30 min static, per API RP 13B-1 |
| Power Supply | AC220V 50Hz (standard) or AC120V 60Hz (USA), ±10% |
| Cell/Cup Material | Stainless steel |
| Compliance Standard | API RP 13B-1, Sec. 7.2 / ISO 10414-1 |
Effective filtration area 22.6 cm² — half the standard API area; double the 30-min filtrate volume to report an equivalent
standard-area fluid loss.